Wiped Film Distillation Challenges 2/3
Thin Feed
Wiped film stills tend to be designed to handle material with at least some viscosity. The systems are often used to distill larger molecules and thicker materials. Because of this, the systems work very well with thick oils but can present challenges if a thinner material has to be handled.
One example is solvent removal. Occasionally a feed material will contain some solvent that needs to be removed before continuing with the distillation. Solvents tend to be very thin and have hardly any viscosity.
This can make it difficult to pump the solvent out of the still system. It is very common to equip wiped film stills with gear pumps. Gear pumps are great at moving thicker fluids but can struggle pumping solvents. Actually, they will pump solvents really well at atmospheric pressure. But trying to push solvents through a check valve and out of a vacuum often proves to be too much.
I recall many times watching the solvent fill up in the distillate leg, then quickly stopping the feed, releasing the vacuum, pumping out the solvent, and turning everything back on. This procedure would be done every hour or so. But this isn't really a solution to the problem.
There are two better options for this type of case. One is to replace the gear pump with a more appropriate pump like a diaphragm pump or a peristaltic pump. The second option is to remove the pump all together and place a receiving vessel of sufficient capacity on the distillate line. Either of these will solve this problem of a thin liquid that won't pump.
If this post is helpful, check out https://lnkd.in/g759iNVj for more posts like this.
Picture is courtesy of Pope Scientific, Inc.