Wiped Film Distillation Mistakes 3/3
No Check Valve
Many applications of wiped film distillation involve thick oils. These oils can be difficult to pump, and sometimes wiped film still producers provide systems that minimize hangups in the feed line.
Because the systems are often used for thick oils, a manufacturer might not include a check valve after the gear pump that feeds the still.
In the case of thinner oils, this can cause a major problem. I have seen cases where a thin oil (like a 1X citrus oil) is sucked uncontrollably into the still body by the vacuum on the still. The feed rate exceeds the capacity of the system and there is no ability to control the distillation at all.
This is fixed by installing a simple in-line check valve after the feed pump and before the inlet of the still. These check valves can be purchased with different size springs, so that the appropriate resistance is provided based on the thickness of the feed oil. But a system without check valves is a system that could prove problematic to some applications.
On the other hand, if you are used to using check valves and you have a very thick oil that won't flow, don't be afraid to pull that check valve out. Thick oils make a column of liquid in the feed line and don't allow leaking, so the only thing a check valve is doing is creating a restriction to flow.
If you found this post helpful, check out my website https://lnkd.in/gjQHSzPr for more wiped film distillation content and information about the master class I teach. It is on sale now until the end of the year.
Picture is courtesy of Pope Scientific, Inc.